ABB Formula Air ACB 4000A Supplier in Navi Mumbai and Thane

ABB Formula Air ACB 4000A Supplier in Navi Mumbai and Thane
A 4000 A air circuit breaker can determine whether an LT panel is ready for commissioning or a plant can restart after a shutdown. For a panel builder in Mahape or a maintenance team in Wagle Industrial Estate, an accurate quote starts with the complete breaker configuration. The pole count, fault rating, trip unit, control voltage and draw-out cradle all affect what needs to arrive at the site.
Ahmedabad Electric Corporation (AEC) supplies genuine ABB Formula Air 4000 A air circuit breakers through AIM Innovations, the ABB dealership in our business network. We support LT panel builders, OEMs, electrical contractors, EPC companies and plant maintenance teams. Selected ABB low-voltage switchgear is available from ready stock. For in-stock orders, estimated delivery is 3–4 days to Navi Mumbai and Thane and 5–6 days to other major Indian metros, subject to configuration, quantity and destination PIN code.
ABB FA4C 4000 A 3-Pole ACB Specifications
ABB lists order code 1SDX204768R1 as a Formula Air FA4C 4000 A, 3-pole, 50 kA electrically operated draw-out ACB with an EK2 LSIG trip unit and display. Use the complete code when requesting a price or checking availability. It identifies the configuration more precisely than a purchase description such as “ABB 4000 A ACB.”
4000 A rated current. Check the selected breaker against the panel builder’s verified design, including busbar capacity, enclosure temperature and terminal arrangement.
50 kA short-circuit rating. ABB’s FA4C data list 50 kA Icu at 400–415 V AC. Icu is the ultimate short-circuit breaking capacity. Also verify Ics, the service breaking capacity, and Icw, the short-time withstand current at the required duration, against the fault study and panel specification.
Three-pole draw-out construction. Verify the breaker’s mounting and terminal orientation. For a replacement, ask for written confirmation that the moving breaker fits the existing cradle. For a new panel, confirm the cradle and required connections in the quotation.
EK2 LSIG with display. L is long-time overload protection, S is short-time short-circuit protection, I is instantaneous short-circuit protection, and G is ground-fault protection. Use the approved protection study to determine settings and verify the required sensing arrangement.
Electrical operating accessories. ABB’s listing specifies an opening coil, closing coil and spring-charging motor suitable for 220–250 V AC/DC. Match the quoted accessories to the panel’s control supply, PLC or interlocking scheme as applicable.
The FA4C can be considered for a main LT incomer, bus coupler or high-current distribution feeder in an appropriately designed assembly. For an APFC installation, identify whether the breaker protects the main panel supply or a dedicated capacitor-bank feeder. The designer can then account for capacitor switching conditions and protection coordination. For a transformer incomer or a bus coupler, confirm the available fault current under the operating conditions specified for the switchboard.
What to Send for a 4000 A ACB Quote
A model-specific quote makes it easier to compare the delivered price and spot missing components before issuing a purchase order. Send the approved bill of materials or the exact ABB reference. For a retrofit, include clear photos of the breaker and cradle nameplates, along with the scheduled shutdown date.
Electrical requirements. Specify system voltage, rated current, prospective fault level, 3-pole or 4-pole design, trip unit and control voltage.
Mechanical requirements. Specify fixed or draw-out construction, terminal orientation and available panel dimensions. If retaining a cradle, include its reference and the existing breaker’s serial or product details.
Scope of supply. Ask the quote to identify the moving breaker, cradle if required, operating coils, charging motor, auxiliary contacts and any position indication or interlocks your drawing calls for.
Commercial and delivery details. Provide quantities, billing information, freight destination and the date the equipment must reach site. Ask for applicable GST, freight, packing, stock status and estimated arrival on the quotation.
For a mixed switchgear order, send the full list in one enquiry. We can check availability for the ACB alongside ABB AF and AX contactors, thermal overload relays, auxiliary contact blocks, MCCBs, MCBs and other low-voltage breakers. Ask us to identify ready-stock items and any lines with longer lead times so you can plan the panel build or release an urgent maintenance order separately.
Industrial Delivery Across Navi Mumbai, Thane and Nearby Areas
Include the MIDC block, plot number, factory gate and PIN code when requesting delivery. This helps confirm the route and receiving arrangements, especially for a crated draw-out breaker.
TTC MIDC and Thane–Belapur Road. Airoli, Digha, Rabale, Ghansoli, Mahape, Kopar Khairane, Turbhe, Pawane and Shiravane, including smaller factory pockets along the corridor.
Navi Mumbai commercial and logistics nodes. Vashi, Sanpada, Juinagar, Nerul, CBD Belapur, Kharghar, Kalamboli, Kamothe, New Panvel and Panvel.
Taloja and the Raigad industrial belt. Taloja MIDC and Additional Taloja, Patalganga and Additional Patalganga, Rasayani, Isambe, Khalapur and Savroli, plus Uran, Dronagiri and the JNPA port and logistics area.
Thane and the Mira–Bhayandar belt. Wagle Industrial Estate, the LBS Marg industrial corridor, Kalwa, Mumbra, Shilphata, Mira Industrial Area, Mira Road and Bhayandar.
Bhiwandi, Kalyan and nearby industrial pockets. Kalyan–Bhiwandi MIDC, Saravali, Gove, Kon, Anjur and Sonale. For warehouse deliveries, include the park name and the receiving bay.
Dombivli, Ambernath and eastern Thane district. Dombivli MIDC Phases I and II, Ulhasnagar, Ambernath MIDC, Additional Ambernath–Anand Nagar, Chikhloli–Morivali, Badlapur MIDC, Murbad and Additional Murbad, plus Shahapur, Asangaon and Vasind.
Nearby Mumbai and Palghar manufacturing areas. Mulund, Bhandup, Powai, Andheri’s Marol MIDC, Vasai East’s Waliv and Sativali clusters, and Boisar–Tarapur. Confirm the estimated arrival date for the specific site.
Pan-India ABB Supply and Stock Checks
AEC coordinates dispatch from Ahmedabad for projects across Maharashtra and India. Other major metro destinations include Delhi NCR, Bengaluru, Chennai, Hyderabad and Kolkata. Gujarat coverage includes Vatva, Odhav, Naroda, Kathwada, Sanand, Sachin, Pandesara, Ankleshwar, Dahej, Vapi and Makarpura, plus smaller GIDC estates such as Dhandhuka, Olpad, Dabhoi and Sankheda.
Request an ABB Formula Air 4000 A ACB quotation from Ahmedabad Electric Corporation at below given contact details. For the featured configuration, quote 1SDX204768R1 and tell us whether you need the cradle, any additional accessories and delivery to a factory, panel shop or project site. On receipt, match the ABB product label and supplied accessories against the quotation and invoice before scheduling installation.
Frequently Asked Questions
Where can I buy an ABB Formula Air 4000 A ACB in Navi Mumbai or Thane?
Contact Ahmedabad Electric Corporation for genuine ABB supply through AIM Innovations. Send order code 1SDX204768R1, the required quantity and the site PIN code for a stock check and delivery estimate.
What affects the price of an ABB FA4C 4000 A draw-out breaker?
Pole count, trip unit, electrical operating accessories, cradle scope and freight can all affect the delivered price. Ask for an itemised quote showing the exact ABB code, included hardware, GST and expected arrival.
What does 50 kA mean on an ABB 4000 A ACB?
For the FA4C at 400–415 V AC, it refers to the rated ultimate short-circuit breaking capacity, Icu. The 4000 A figure is the rated current. The panel designer also checks Ics and Icw against the installation’s requirements.
What does EK2 LSIG protection include?
EK2 provides protection and measurement with a display. LSIG covers long-time overload, short-time short-circuit, instantaneous short-circuit and ground-fault protection. The approved coordination study determines the settings.
Can I use this ABB 4000 A ACB with my existing draw-out cradle?
Have the panel builder verify compatibility using the existing cradle and breaker references, terminal orientation and interlock arrangement. Send both nameplates before ordering a moving breaker for a retrofit.
Can I order ABB contactors, overload relays and MCCBs with the ACB?
Yes. Send all ABB part numbers in one enquiry. Estimated delivery for in-stock orders is 3–4 days to Navi Mumbai and Thane and 5–6 days to other major Indian metros, subject to availability and PIN-code confirmation.
Check out our other ABB blogs :-
https://www.aecswitchgear.com/blog/abb-acs580-vfd-dealer-in-surat
https://www.aecswitchgear.com/blog/abb-switchgear-rate-list-surat
https://www.aecswitchgear.com/blog/how-to-choose-an-abb-drive-for-a-cooling-tower-fan
https://www.aecswitchgear.com/blog/abb-contactor-supplier-in-rajkot
https://www.aecswitchgear.com/blog/abb-acs580-vfd-dealer-in-surat
https://www.aecswitchgear.com/blog/abb-soft-starter-price-mehsana
https://www.aecswitchgear.com/blog/genuine-abb-contactor-supplier-in-rajkot
https://www.aecswitchgear.com/blog/abb-pstx-soft-starter-price-in-dahej-gidc
https://www.aecswitchgear.com/blog/abb-af-and-ax-contactor-price-list-for-noida-and-gurugram
https://www.aecswitchgear.com/blog/abb-tmax-xt-and-formula-dsa-mccb-bulk-dealer-serving-mumbai
https://www.aecswitchgear.com/blog/abb-formula-dsa-dsp-mccb-distributor-delhi-ncr-faridabad
https://www.aecswitchgear.com/blog/abb-adam-and-eva-safety-sensor-distributor-in-pune-and-chakan
Contact us :-
Mr. Ravikant Gupta :- +91 99742 83830 & sales@aiminnovations.in