If you’re pricing ABB contactors for a panel build in Noida or replacing a motor starter in IMT Manesar, start with the full ABB order code. Two contactors can share the same 9 A motor-duty rating and still require different control supplies. That difference matters when the replacement has to work with the existing wiring, overload relay and panel layout.
Ahmedabad Electric Corporation (AEC) supplies genuine ABB low-voltage switchgear through AIM Innovations, the ABB distributor in our business network. We serve LT panel builders, machine OEMs, automation integrators and plant maintenance teams from Ahmedabad. Selected contactors, relays and industrial breakers are held in ready stock. For confirmed in-stock orders, we estimate 3–4 days to Noida and Gurugram industrial addresses and 5–6 days to other major Indian metros, subject to the delivery PIN code.
ABB AF and AX contactor price references
ABB India’s electrification price list effective 10 February 2026 gives the following unit list-price references. Request a current AEC quotation to confirm the net price, GST, freight and availability for your quantity.
ABB contactor | ABB order code | Control supply | Published list price |
|---|---|---|---|
AX09-30-10-80 | 1SBL901074R8010 | 220–230 V AC at 50 Hz or 230–240 V AC at 60 Hz | ₹1,870 |
AF09-30-10-13 | 1SBL137001R1310 | 100–250 V AC at 50/60 Hz or 100–250 V DC | ₹4,810 |
Both references have three normally open main poles, one normally open auxiliary contact and a 9 A AC-3 rating at 415 V under ABB’s stated conditions. If you are comparing prices for an OEM batch, match the coil code and auxiliary configuration first. Then compare the delivered cost of the contactor, overload relay and any add-on contacts.
When to choose ABB AF or AX for a motor feeder
Use the approved AX reference for a like-for-like spare when the existing starter, control voltage and accessories match. Consider AF for a new design where a wide-range electronic coil or built-in surge suppression meets the panel specification. The 100–250 V AC/DC control range belongs to the AF09 variant above. Check the exact coil suffix on every AF line in your order.
Select by motor duty. Use the motor’s full-load current, operating voltage and utilisation category. For normal starting and stopping of a squirrel-cage motor, check the AC-3 rating. If the machine uses frequent inching, plugging or reversing under load, verify the applicable duty and switching frequency with your panel designer.
Check the actual control supply. A 415 V motor feeder can use a 230 V AC coil or a separate DC control supply. A panel with a 24 V DC control circuit needs a coil reference that explicitly covers 24 V DC. Share the control diagram when the coil marking is unclear.
Count auxiliary contacts by function. A built-in normally open contact may be allocated to a holding circuit or run indication. List any additional contacts required for PLC status or interlocking and verify the compatible block and mounting position.
Choose the overload relay and upstream device together. Match the overload adjustment range and trip class to the motor and starter arrangement. If the specification calls for Type 2 coordination, check ABB’s tables for the exact contactor, overload relay and short-circuit protective device at the project fault level.
Check retrofit fit before ordering. Compare mounting centres, terminal positions, available wiring space and interlock compatibility. For a reversing or star-delta starter, send all the contactor references so the proposed replacement can be checked against the complete assembly.
Request an itemised ABB wholesale quote
Send your bill of materials with the ABB code, coil voltage, quantity and delivery PIN code on each line. For a breakdown spare, attach a readable photo of the device label and coil marking. For a repeat build, specify the first batch quantity and the date your panel shop needs the balance.
For panel builders. Include relay ranges, auxiliary blocks and interlocks on the same enquiry. Ask for stock status by item so a small accessory can be accounted for before factory acceptance testing.
For maintenance buyers. Mark the shutdown quantity separately from replenishment stock. Ask for the dispatch estimate and applicable warranty details against the quoted reference.
For a complete ABB panel. Add thermal or electronic overload relays, manual motor starters, auxiliary contact blocks, Tmax XT MCCBs, Emax 2 ACBs, miniature circuit breakers and residual current devices. Confirm the required rating and accessories for each breaker.
Noida, Gurugram and nearby NCR industrial deliveries
For fast delivery, include the estate or sector, plot number and receiving gate. The 3–4-day estimate applies to confirmed stocked orders on covered Noida and Gurugram routes. Ask for the applicable estimate for adjoining districts when you submit the PIN code.
Noida and Noida Phase II. Sectors 6, 7, 8, 9 and 10, the Sector 57–60 and 63–65 industrial belts, Sectors 80–83, and the Hosiery Complex in Phase II.
Greater Noida and Gautam Buddha Nagar. Surajpur, Kasna, Surajpur Site IV, EPIP Kasna, Ecotech industrial sectors, and factory addresses in the Dadri and Sikandrabad corridors.
Gurugram and Manesar. Udyog Vihar Phases I–V, Electronic City in Sector 18, Pace City I and II, Kadipur, Basai, IMT Manesar and the Binola–Bilaspur industrial belt.
Nearby Haryana routes. Sohna and Roz Ka Meo, Dharuhera, IMT Bawal, Faridabad, Ballabgarh, Palwal, Bahadurgarh, Kundli, Rai and Barhi.
Ghaziabad, Delhi and adjoining Rajasthan. Sahibabad Site IV, Meerut Road Site III, Loni Industrial Estate, Tronica City, Udyog Kunj at Dasna, Okhla, Bawana, Naraina, Bhiwadi, Chopanki, Khushkhera and Neemrana.
Gujarat GIDC and pan-India dispatch
Ahmedabad and North Gujarat. Odhav, Vatva, Naroda, Kathwada, Sanand-II (Bol), Dholka, Dhandhuka, Chhatral, Kadi and Mehsana.
Vadodara and South Gujarat. Makarpura, Nandesari, Ranoli, Por–Ramangamdi, Savli, Halol, Ankleshwar, Panoli, Dahej, Saykha, Sachin, Pandesara, Khatodara, Hazira, Vapi, Sarigam and Umargam.
Saurashtra and Kutch. Aji, Lodhika (Metoda), Gondal, Kuvadva, Rafaleshwar, Dared, Chitra, Sihor and the Anjar–Gandhidham belt.
Major cities across India. Mumbai, Navi Mumbai, Pune, Bengaluru, Chennai, Hyderabad, Kolkata, Jaipur, Indore, Coimbatore and Kochi. For split orders, share the quantity, PIN code and required date for each site.
Call AEC at +91 97141 87752 for a current ABB AF or AX contactor price and ready-stock check for Noida or Gurugram. Include the overload relay and accessory references if you need a complete feeder quote.
Frequently asked questions
Why does my ABB AF09 quote differ from the published price list?
The dated list price is a reference. Your delivered quote depends on the exact coil and auxiliary configuration, order quantity, GST, freight and availability. Ask for each line to be identified by ABB order code.
Can an AF09-30-10-13 replace an AX09-30-10-80?
Have your panel engineer check the control supply, motor duty, overload relay, dimensions and auxiliary connections. The matching 9 A AC-3 ratings alone cannot establish retrofit compatibility.
Can I run a 415 V motor using the AX09-30-10-80?
The main contacts are rated 9 A AC-3 at 415 V under ABB’s stated conditions. At 50 Hz, the coil needs 220–230 V AC. Verify both circuits against the starter drawing.
Which ABB overload relay should I buy with a 9 A contactor?
Use the motor nameplate current and starter arrangement to select the relay setting range. Then verify the mounting fit, trip class and approved combination with the upstream fuse or breaker.
Does an AF09 with a built-in 1NO contact give me a spare PLC signal?
Check whether the panel already uses that contact for the holding circuit or another function. If the PLC needs a separate status contact, specify a compatible auxiliary block and verify its rating.
Can I get one shutdown spare in Manesar and a bulk batch in Noida?
Yes. Send each site’s quantity, PIN code, receiving hours and required date. We can quote separate dispatches and confirm stock for the urgent item before you schedule the shutdown.
Check out our other ABB blogs :-
https://www.aecswitchgear.com/blog/abb-acs580-vfd-dealer-in-surat
https://www.aecswitchgear.com/blog/abb-switchgear-rate-list-surat
https://www.aecswitchgear.com/blog/how-to-choose-an-abb-drive-for-a-cooling-tower-fan
https://www.aecswitchgear.com/blog/abb-contactor-supplier-in-rajkot
https://www.aecswitchgear.com/blog/abb-acs580-vfd-dealer-in-surat
https://www.aecswitchgear.com/blog/abb-soft-starter-price-mehsana
https://www.aecswitchgear.com/blog/genuine-abb-contactor-supplier-in-rajkot
https://www.aecswitchgear.com/blog/abb-pstx-soft-starter-price-in-dahej-gidc
Contact us :-
Mr. Ravikant Gupta :- +91 99742 83830 & sales@aiminnovations.in