Buy L&T Lauritz Knudsen MCX 4 pole contactor for DG panel Surat Hazira

Buy L&T Lauritz Knudsen MCX 4-Pole Contactors for DG Panels in Surat and Hazira
If you’re building a mains-to-generator changeover panel in Surat or Hazira, ask for the Lauritz Knudsen MCX 4-pole contactor by its full catalogue reference and coil voltage. An automatic mains failure (AMF) panel can be ready for testing and still be held up by an incompatible interlock, a missing auxiliary contact or the wrong coil. Confirming the complete assembly before ordering can save a second dispatch and a return visit to site.
Ahmedabad Electric Corporation (AEC) handles enquiries through Reliable Electrical, the group’s authorised Lauritz Knudsen distribution business. We supply genuine contactors and low-voltage switchgear to panel builders, genset OEMs, automation integrators and plant maintenance teams. Lauritz Knudsen was formerly known as L&T Switchgear, so you can send us either the current catalogue number or a readable photo of your legacy L&T nameplate. We check ready stock by reference and dispatch from Ahmedabad to Surat, across Gujarat and throughout India.
What the MCX range offers for DG changeover panels
The MCX 4-pole range spans 18–900 A AC-1. In a contactor-based transfer panel, an automatic source transfer controller manages when the load moves between mains and an approved backup source, such as a diesel generator (DG) or UPS. The contactors do the power switching under the panel’s approved control and interlock scheme.
Main and auxiliary contacts. The standard 4NO version has four normally open power poles. Some models, including the MCX 47, also have 2NO + 2NC auxiliary contacts. Lauritz Knudsen separately offers 18–40 A models with 2NO + 2NC power contacts. State both requirements on your enquiry.
Mechanical interlocking. Lauritz Knudsen lists a compact mechanical interlock arrangement for models up to 80 A. Confirm the kit for the exact contactor pair and check how it fits with any auxiliary blocks. For larger frames, have your panel designer specify and verify the approved interlocking arrangement.
Common accessories. Some MCX accessories are shared with the MNX range. Confirm the accessory code, frame and mounting position before reusing stock. This matters when an existing side-mounted block must fit beside an interlocked contactor.
How to select an MCX contactor for your generator
Use Lauritz Knudsen’s DG selection chart alongside the approved single-line diagram and load schedule. Give your engineer the generator rating, the characteristics of the load being transferred and the panel’s short-circuit requirements.
Start with DG kVA and voltage. At rated output, a three-phase 125 kVA, 415 V generator delivers approximately 174 A. Use that figure as a starting point. Check the manufacturer’s DG selection chart, maximum transferred load, enclosure temperature and any applicable derating before choosing the frame.
Check the switching duty. AC-1 ratings apply to non-inductive or slightly inductive loads. If the transfer panel feeds motors, transformers or UPS inputs, have the panel designer assess the actual switching duty and inrush. A motor-duty rating or an automatic transfer assembly rating needs its own verification.
Confirm the neutral and earthing design. A four-pole device can switch three phases and a neutral where the approved design calls for it. The engineer should confirm the neutral arrangement against the generator earthing, source bonding and earth-fault protection scheme.
Specify coil voltage and control feedback. Send the coil voltage, AC or DC supply type and frequency where applicable. A panel with a 415 V main supply may use a different control voltage. Include the required position feedback, alarm contacts and interlock accessories.
Check the complete transfer assembly. For open-transition operation, verify that the approved scheme opens one source before closing the other. Confirm electrical and mechanical interlocking, upstream protection and the assembly’s short-circuit capability. If the tender calls for IEC 60947-6-1 transfer switching equipment, check compliance for the complete equipment. The MCX component is specified under IEC 60947-4-1.
Hazira and Surat industrial delivery
From an AMF retrofit in Bhatpor to a new DG panel in Pandesara, send the estate name, plot number, site PIN code and goods-receiving hours. For confirmed in-stock orders, the estimated delivery window is 4–5 days across Gujarat, including Surat and Hazira.
Hazira notified area and western industrial corridor: Hazira, also listed as Hajira, Bhatpor GIDC, Ichchapore, also known as Ichhapore, and factory addresses around Kawas, Mora and Magdalla.
Smaller Hazira-area delivery localities: Damka, Bhatlai, Vansva, Rajgari, Suvali (Sunvali) and Limla. For restricted industrial sites, include the receiving gate and the contact person on the enquiry.
Surat city and textile estates: Sachin GIDC, Apparel Park–Sachin SEZ, Pandesara GIDC, Katargam GIDC and Khatodara GIDC.
Outer Surat industrial routes: Olpad and Bardoli GIDC, plus factory addresses in Palsana, Kadodara, Jolwa, Tatithaiya, Kim, Pipodara and Kosamba.
Smaller GIDC listings in the Surat region: Doswada and Valod. For Nizar, Miyawadi and the Miyawadi MSME/Women Development Park, use the exact site address so we can confirm delivery against the PIN code.
Gujarat and pan-India switchgear supply
For confirmed in-stock orders outside Gujarat, our delivery estimate is 5–6 days to serviceable destinations. We can quote a single shutdown spare, an interlocked contactor pair or a full panel bill of materials.
Ahmedabad, Gandhinagar and Mehsana: Odhav, Naroda, Vatva, Kathwada, Sanand-II (Bol), Chhatral, Kadi and Mehsana.
Vadodara, Bharuch and South Gujarat: Makarpura, Nandesari, Savli, Vaghodia, Halol, Ankleshwar, Panoli, Dahej, Saykha, Navsari, Vapi, Sarigam and Umargam.
Saurashtra and Kutch: Aji, Lodhika (Metoda), Gondal, Kuvadva, Dared, Chitra and the Anjar–Gandhidham belt.
Major Indian cities and industrial belts: Mumbai and Navi Mumbai, Pune, Delhi NCR, Bengaluru, Hyderabad, Chennai, Kolkata, Jaipur, Indore, Coimbatore and Kochi. Industrial destinations include Taloja, Chakan, IMT Manesar, Peenya, Patancheru and Oragadam.
Request an MCX price and stock check
For a new DG panel: Send the generator kVA, system voltage, load schedule, coil supply and approved contact configuration. List the controller, auxiliary blocks, interlock and upstream breaker on separate lines.
For an existing panel: Send photos of both contactor nameplates, the coil label and the interlock mounting. State whether you need one spare or an approved matched pair.
For a full switchgear order: Add Lauritz Knudsen d sine MCCBs, C-Power ACBs, MNX motor contactors, overload relays, MCBs and panel accessories to the same enquiry. Ask for an itemised quote covering GST, freight, available quantities and the expected arrival date.
Call AEC at +91 95371 65041 or submit an online enquiry for an MCX 4-pole contactor price for Surat or Hazira. If the panel has a factory acceptance test or shutdown date, include it with your stock request.
Frequently asked questions
What information do I need for a Lauritz Knudsen MCX price in Hazira?
Share the model or catalogue number, coil voltage, quantity and site PIN code. For a changeover pair, include the interlock and auxiliary blocks so the quote covers the complete delivered requirement.
Is the MCX 47 a 900 A contactor with 2NO + 2NC power contacts?
The MCX 47, base reference CS94291, is listed at 900 A AC-1 with four normally open main power poles. Its 2NO + 2NC designation in the catalogue’s auxiliary column refers to the auxiliary contacts.
Can I use the same contactor frame on the mains and DG sides?
Check each side against its design duty and prospective fault conditions. If the panel uses a mechanically interlocked pair, have the designer verify that the two references and the specified interlock work together.
Can a 4-pole MCX solve a floating-neutral problem in a DG panel?
A four-pole model provides a pole for neutral switching where the design requires it. Have the engineer verify the source bonding, earthing and control supply before choosing the switching arrangement or the coil voltage.
Can I reuse an MNX auxiliary block on an MCX contactor?
Some accessories are shared. Send the existing block code and proposed MCX frame, then confirm the mounting position and clearances, especially when a mechanical interlock is fitted.
Can I replace only one MCX contactor in an existing AMF panel?
A single-unit replacement may be possible after checking the original reference, coil, contact arrangement, mounting and interlock fit. Have the commissioning team verify the complete transfer sequence after replacement.
Check out our other Lauritz Knudsen blogs :-
https://www.aecswitchgear.com/blog/lauritz-knudsen-dealer-in-jamnagar
https://www.aecswitchgear.com/blog/lauritz-knudsen-dsine-mccb-dealer-sanand-gidc
https://www.aecswitchgear.com/blog/lauritz-knudsen-c-power-acb-quotation-makarpura-gidc-vadodara
https://www.aecswitchgear.com/blog/lauritz-knudsen-switchgear-dealer-mehsana
https://www.aecswitchgear.com/blog/how-to-choose-a-lauritz-knudsen-acb-frame-rating
https://www.aecswitchgear.com/blog/lauritz-knudsen-distributor-in-bavla-gidc
https://www.aecswitchgear.com/blog/lauritz-knudsen-tripper-mcb-wholesale-supplier
https://www.aecswitchgear.com/blog/wholesale-lauritz-knudsen-electrical-supplier-vadodara-baroda
https://www.aecswitchgear.com/blog/authorized-lauritz-knudsen-switchgear-wholesale-dealer-with-pan-india-delivery
https://www.aecswitchgear.com/blog/genuine-lauritz-knudsen-dealer-near-dared-gidc-jamnagar
https://www.aecswitchgear.com/blog/lauritz-knudsen-mnx-contactor-supplier-in-surat
https://www.aecswitchgear.com/blog/how-to-select-a-lauritz-knudsen-mccb-for-a-machine-feeder
https://www.aecswitchgear.com/blog/buy-lauritz-knudsen-mccb-online-surat
Get our brochure for more information.
Contact us:-
Mr. Pratik Baid :- +91 95371 65041 & reliableelectrical2612@gmail.com