If you’re sourcing ABB Tmax XT or Formula DSA MCCBs in bulk for a Mumbai project, send the breaker schedule with your enquiry. A quote that says only “ABB 160 A MCCB” leaves the pole count, breaking capacity, trip unit and accessories open. Those details determine whether the breaker fits the approved panel and whether the complete order can reach your shop before testing.
Ahmedabad Electric Corporation (AEC) supplies genuine ABB low-voltage switchgear through AIM Innovations, the authorised ABB distributor in our business network. We serve LT panel builders, APFC panel manufacturers, machine OEMs, automation integrators and maintenance teams from Ahmedabad. Selected MCCBs, contactors, relays and industrial breakers are held in ready stock. For confirmed in-stock orders, estimated delivery is 3–4 days to Mumbai and covered Mumbai-area industrial addresses and 5–6 days to other major Indian metros, subject to the site PIN code.
ABB Tmax XT vs Formula DSA for LT panels
SACE Formula DSA for standard distribution feeders. ABB lists the range from 15 A to 630 A across frames A0 through A3. Fixed thermal-magnetic TMF variants suit repetitive distribution builds where the approved protection study accepts fixed overload and short-circuit thresholds. Check the model’s breaking capacity, pole count and accessories before standardising it across a batch.
SACE Tmax XT for projects with specific protection or monitoring requirements. ABB’s IEC range spans 16 A to 1,600 A across XT1 through XT7. Depending on the reference, it offers thermal-magnetic or Ekip electronic trip units. Specify the trip functions, metering and communication hardware when quoting a monitored incomer or a coordinated outgoing feeder.
Both ranges can feature in one approved panel design. A panel builder may use a Tmax XT with the specified electronic protection on an incomer and Formula DSA TMF breakers on repeat outgoing circuits. Confirm the fault level, selectivity and panel assembly rating before releasing that combination for production.
What to check before placing a bulk MCCB order
Keep frame size and trip rating separate. A breaker in a 160 A frame can be supplied with a lower-rated trip unit. Put the frame, trip-unit reference and required adjustment range on the bill of materials. Have your panel designer confirm the load current, conductor capacity and enclosure conditions.
Quote breaking capacity at the system voltage. Record the prospective fault current at the breaker position and the required Icu, or ultimate breaking capacity, at the actual voltage. Check Ics, the service breaking capacity, where specified. If the design relies on an upstream breaker for backup protection, verify the exact pair in ABB’s coordination tables.
Check selectivity on the actual devices. For a machine feeder that should trip without taking down the main panel, share the upstream and downstream breaker references, trip settings and fault level with your design team. Two breakers with matching catalogue kA figures can behave differently in a coordinated system.
Confirm poles, mounting and terminal layout. Specify 3P or 4P and the required neutral switching and protection. For a retrofit, compare mounting centres, terminal spacing, busbar alignment and door clearance. List the mounting version and terminal arrangement on the order.
Specify APFC duty and accessories. For an automatic power factor correction panel, share the capacitor bank or stage kVAr, voltage, switching arrangement and protection requirements. If the job needs a rotary handle, shunt release, auxiliary contact, trip alarm or terminal spreader, list those separately. Include the control voltage for any release coil.
How to get a comparable ABB wholesale quote
For a production batch, submit one line per breaker configuration. If eight panels each need one incomer and three identical outgoing breakers, quote eight incomers and 24 outgoing breakers on separate lines. Add commissioning and maintenance spares as their own quantities.
Send the exact ABB order codes. For a new build, attach the approved breaker schedule or single-line diagram. For a replacement, send a readable picture of the nameplate, trip unit and fitted accessories.
Ask for unit price, GST, freight and stock by reference. Review the complete delivered cost, including accessories. For a phased project, give the quantity required at each site and the latest acceptable arrival date.
Confirm what can ship together. If an approved breaker is ready and its handle or release has a separate lead time, ask for an itemised dispatch estimate. At incoming inspection, match the ABB order code and device markings to the carton and invoice.
Mumbai, Navi Mumbai, Thane and nearby industrial delivery
Include the estate, sector, plot number and gate receiving hours on your enquiry. We confirm the delivery window by PIN code, including smaller estates and sites that receive material through a designated gate.
Mumbai: Andheri East and Marol MIDC, plus industrial addresses in Saki Naka, Powai, Goregaon, Malad and the Bhandup–Mulund belt.
Navi Mumbai and Trans Thane Creek (TTC) MIDC: Airoli, Rabale, Ghansoli, Mahape, Kopar Khairane, Pawane and Turbhe. We also quote for Kalamboli and Panvel deliveries.
Thane and the eastern industrial belt: Wagle Industrial Estate, Dombivli MIDC, Ambernath, Additional Ambernath–Pale, Badlapur, Kalyan, Bhiwandi and Murbad.
Palghar and the northern corridor: Vasai–Virar, Waliv, Sativali, Pelhar, Palghar and Boisar–Tarapur MIDC.
Raigad industrial routes: Taloja and Additional Taloja, Patalganga, Additional Patalganga, Bhokarpada, Rasayani, Khalapur, Roha and Mahad.
Gujarat GIDC and pan-India ABB supply
AEC can quote for separate shipments when breakers are assembled in Mumbai and commissioned elsewhere. Share the delivery split with your bulk enquiry.
Ahmedabad and North Gujarat: Odhav, Vatva, Naroda, Kathwada, Sanand-II (Bol), Dholka, Dhandhuka, Chhatral, Kadi and Mehsana.
Vadodara, Bharuch and South Gujarat: Makarpura, Nandesari, Ranoli, Savli, Vaghodia, Halol, Ankleshwar, Panoli, Dahej, Sachin, Pandesara, Hazira, Bardoli, Navsari, Vapi, Pardi, Dungra, Sarigam and Umargam.
Saurashtra and Kutch: Aji, Lodhika (Metoda), Gondal, Kuvadva, Rafaleshwar, Dared, Chitra, Sihor, Anjar and Gandhidham.
Other Maharashtra and Indian centres: Pune, Chakan, Bhosari, Ranjangaon, Nashik, Ambad, Satpur, Nagpur, Delhi NCR, Bengaluru, Chennai, Hyderabad, Kolkata, Jaipur, Indore and Coimbatore.
Add contactors, relays and distribution gear to the same quote
For a complete ABB panel order, include AF and AX contactors, thermal or electronic overload relays, manual motor starters, auxiliary blocks, Emax 2 air circuit breakers, MCBs and residual current devices. For motor-control lines, send the coil voltage, motor current and overload range. For breaker lines, include the pole count, trip specification and accessories.
Call Ahmedabad Electric Corporation at for a Tmax XT or Formula DSA bulk price and ready-stock check for Mumbai. Have your ABB references, quantities, site PIN code and required date ready.
Frequently asked questions
What is the ABB 160 A MCCB bulk price in Mumbai?
Request a price by complete ABB order code. A 160 A offer can vary with the range, breaking capacity, pole count and trip unit. Ask for unit pricing and the total with GST, accessories and freight.
Can I replace a Formula DSA breaker with a Tmax XT of the same amperage?
Have your panel designer approve the replacement. Compare the trip curves, voltage-specific breaking capacity, mounting, terminals and any installed accessories. Recheck coordination with the other protective devices in the panel.
Can I quote a Tmax XT with SCADA monitoring?
Yes. Specify the measurements, status points and protocol required. Ask for the compatible Ekip trip unit, communication hardware and any auxiliary power requirements on the same quote.
What should I send for an ABB MCCB quote for an APFC panel?
Send the bank and stage kVAr, operating voltage, design current, fault level and switching arrangement. Identify whether the breaker is the panel incomer or a stage feeder.
Does ABB’s 200 kA figure apply to every Tmax XT?
The figure is a range maximum. Use the datasheet for the exact order code to confirm the breaking capacity at your actual system voltage and under the required standard.
Can AEC deliver to Mahape or Taloja before panel testing?
For confirmed stocked material, the covered Mumbai-area delivery estimate is 3–4 days. Send the plot number, PIN code, testing date and list of critical items so we can confirm the expected arrival.
Check out our other ABB blogs :-
https://www.aecswitchgear.com/blog/abb-acs580-vfd-dealer-in-surat
https://www.aecswitchgear.com/blog/abb-switchgear-rate-list-surat
https://www.aecswitchgear.com/blog/how-to-choose-an-abb-drive-for-a-cooling-tower-fan
https://www.aecswitchgear.com/blog/abb-contactor-supplier-in-rajkot
https://www.aecswitchgear.com/blog/abb-acs580-vfd-dealer-in-surat
https://www.aecswitchgear.com/blog/abb-soft-starter-price-mehsana
https://www.aecswitchgear.com/blog/genuine-abb-contactor-supplier-in-rajkot
https://www.aecswitchgear.com/blog/abb-pstx-soft-starter-price-in-dahej-gidc
https://www.aecswitchgear.com/blog/abb-af-and-ax-contactor-price-list-for-noida-and-gurugram
Contact us :-
Mr. Ravikant Gupta :- +91 99742 83830 & sales@aiminnovations.in