Buy Schneider Acti9 xC60 D-Curve MCBs in Bulk in India

Buy Schneider Acti9 xC60 D-Curve MCBs in Bulk in India — 1P 63 A, 3P 40 A and 4P 32 A
When you buy breakers for a batch of panels, a wrong trip curve or order code can delay every panel on the shop floor. Ahmedabad Electric Corporation (AEC) is an authorised Schneider Electric distributor supplying genuine Acti9 xC60 miniature circuit breakers (MCBs) to panel builders, OEMs, automation integrators and industrial buyers across India. Order directly from our Ahmedabad team for delivery to your panel shop, factory or project site.
We keep selected Schneider industrial breakers, distribution products and control components in ready stock. For confirmed in-stock orders, our delivery estimates are 4–5 days on covered industrial routes in major Indian cities and 5–6 days for metro-city deliveries. Send your site PIN code and required date when requesting a quote.
Order the exact Acti9 xC60 D-curve breaker
Schneider lists these pole and current combinations under two standards. Put the full reference on your bill of materials (BOM) and purchase order so your engineering team, buyer and stores team can match the same item.
1P 63 A D-curve: A9N1P63DIN is listed at 6 kA Icu under IS/IEC 60947-2. A9N1P63DGN is listed at 10 kA Icn under IS/IEC 60898-1. Ask us to confirm lead time for the exact 63 A reference.
3P 40 A D-curve: A9N3P40DIN is listed at 15 kA Icu under IS/IEC 60947-2. A9N3P40DGN is listed at 10 kA Icn under IS/IEC 60898-1.
4P 32 A D-curve: A9N4P32DIN is listed at 15 kA Icu under IS/IEC 60947-2. A9N4P32DGN is listed at 10 kA Icn under IS/IEC 60898-1.
Icu and Icn are short-circuit breaking ratings defined under different standards. Verify the required standard, rating and operating voltage together on the exact datasheet. A 15 kA catalogue entry alone cannot determine whether a breaker is suitable for your panel.
When should you specify a D-curve MCB?
A D-curve breaker has a higher instantaneous magnetic pickup than a C-curve breaker. That can suit loads with brief, high starting currents, such as certain transformers and motor circuits. Your panel designer should check both sides of the decision. The breaker needs to tolerate normal energisation and still meet the required fault clearance time.
Check inrush and fault current. Compare the magnitude and duration of the starting current with the manufacturer’s time-current curve. Verify the minimum fault current at the far end of the circuit and the maximum prospective fault current at the breaker.
Match the poles to the circuit. Review the single-line diagram for the required phase and neutral arrangement. Check the exact pole configuration, especially where the specification distinguishes a four-pole breaker from a 3P+N device.
Check conductors and coordination. Confirm cable capacity under the actual installation conditions, enclosure temperature and upstream protection. Use Schneider’s coordination data when the design relies on selectivity or backup protection.
Quote the accessories with the breaker. List any comb busbar, auxiliary contact or trip indication contact by reference. For a motor feeder, include the contactor and overload protection specified in the design so the entire assembly can be procured together.
How to buy Schneider MCBs in bulk from AEC
Send a quantity against each order code. For repeat builds, include units per panel, number of panels and spare stock. Twenty panels using two 3P units each, plus four maintenance spares, require 44 breakers on that line.
Request a line-item bulk quotation. Ask for unit pricing, GST, freight, available quantity and lead time. If your BOM mixes C-curve and D-curve devices, give each its own line so the quote can be checked against the approved drawing.
Plan delivery around your build. Flag the breakers needed for factory acceptance testing and give us your gate receiving hours. For a phased project, share the required date and quantity for each site so dispatch can be quoted accordingly.
Make incoming inspection straightforward. Match the manufacturer reference, pole count, rated current and curve on the device to the carton label and purchase order. For shutdown spares, send a readable nameplate photo with the enquiry.
Industrial delivery across India
We supply major manufacturing belts and smaller estates. Include the estate phase, plot number and PIN code for an arrival estimate.
Delhi NCR and Haryana: Okhla, Bawana and Narela in Delhi, Noida and Greater Noida’s Surajpur–Kasna belt, Sahibabad in Ghaziabad, Gurugram’s IMT Manesar, Faridabad, Kundli, Rai and Bahadurgarh.
Mumbai, Navi Mumbai, Pune and Nashik: TTC MIDC, Taloja, Ambernath, Bhosari, Chakan, Talegaon, Ranjangaon, Kurkumbh, Ambad and Satpur.
Bengaluru, Mysuru, Chennai and Hosur: Peenya, Bommasandra, Jigani, Harohalli, Nanjangud, Ambattur, Guindy, Sriperumbudur, Oragadam, Pillaipakkam, Thervoykandigai and Hosur SIPCOT.
Hyderabad and other southern centres: Jeedimetla, Nacharam, Cherlapally, Patancheru and Pashamylaram, plus Kurichi in Coimbatore, Kalamassery near Kochi and Gajuwaka in Visakhapatnam.
North and Central India: Sitapura and Bagru near Jaipur, Focal Point in Ludhiana, Panki in Kanpur, Amausi in Lucknow, Pithampur near Indore, Mandideep near Bhopal and Butibori near Nagpur.
East and Northeast India: Sankrail and Uluberia near Kolkata and Howrah, Mancheswar in Bhubaneswar, Adityapur near Jamshedpur, Tupudana in Ranchi, Urla in Raipur, Fatuha near Patna and Bamunimaidam in Guwahati.
Gujarat GIDC delivery from Ahmedabad
Ahmedabad, Gandhinagar and Mehsana: Odhav, Vatva, Naroda, Kathwada, Sanand-II (Bol), Chharodi, Dholka, Dhandhuka, Chhatral and Kadi.
Vadodara, Halol and Bharuch: Makarpura, Nandesari, Vaghodia, Por–Ramangamdi, Halol, Ankleshwar, Panoli, Dahej, Saykha and Vilayat.
Surat, Navsari and Vapi: Sachin, Pandesara, Khatodara, Hazira, Navsari, Pardi, Sarigam and Umargam.
Rajkot, Morbi, Jamnagar and Bhavnagar: Aji, Lodhika (Metoda), Gondal, Kuvadva, Rafaleshwar, Dared, Chitra and Sihor.
Add switchgear and automation to the same enquiry
Power distribution: Acti9 RCCBs and RCBOs, Easy9 distribution products, EasyPact CVS and ComPacT NSX MCCBs, and MasterPacT MTZ air circuit breakers.
Motor control and automation: TeSys Deca contactors and overload relays, Altivar variable frequency drives, Modicon PLCs, Harmony controls and EasyLogic power meters.
Call AEC at +91 97141 87752 for Schneider Acti9 xC60 bulk pricing. Have your order codes, quantities and delivery PIN code ready so we can quote the material and delivery together.
Frequently asked questions
What is the bulk price of Schneider Acti9 xC60 D-curve MCBs in India?
Request a delivered quote by exact order code. The standard, quantity, GST and freight affect your total. For repeat production, include your estimated monthly requirement and first dispatch quantity.
Can an A9N3P40DGN replace an A9N3P40DIN?
Ask your panel designer to approve the substitution. Both are 3P 40 A D-curve breakers, but their breaking ratings are declared under different standards. Check the project specification and fault level at the operating voltage.
Can I swap a C40 breaker for a D40 if it trips when a machine starts?
First confirm what causes the trip. Have your engineer compare measured inrush and fault-loop conditions against the exact curves. A D40 has a higher magnetic pickup and changes how the circuit responds to a fault.
Does the xC60 D-curve MCB provide earth-leakage protection?
The MCB provides overload and short-circuit protection. Where the design requires residual current protection, specify a suitable RCCB, RCBO or compatible residual current add-on and confirm coordination.
What minimum quantities should I plan for on a mixed bulk order?
Schneider’s published schedule lists minimum order quantities of 12 for 1P, four for 3P and three for 4P. Ask AEC to confirm the order increment and available quantity for each code.
Can AEC deliver one bulk order to multiple industrial sites?
Send a separate quantity, PIN code and required date for each site. Ask for a site-wise freight and delivery estimate, especially when one plant has a shutdown or panel testing deadline.
Check out our other Schneider electric blogs :-
https://www.aecswitchgear.com/blog/schneider-masterpact-acb-supplier-hazira-surat
https://www.aecswitchgear.com/blog/schneider-altivar-pump-drive-supplier-ankleshwar-gidc
https://www.aecswitchgear.com/blog/schneider-compact-nsx-mccb-quotation-dholera-sir
https://www.aecswitchgear.com/blog/schneider-electric-industrial-switchgear-supplier-hazira
https://www.aecswitchgear.com/blog/schneider-tesys-contactor-coil-price-vapi-gidc
https://www.aecswitchgear.com/blog/schneider-electric-switchgear-supplier-mundra
https://www.aecswitchgear.com/blog/schneider-distributor-thane-belapur-midc
https://www.aecswitchgear.com/blog/schneider-hmi-quotation-for-kalol-gidc
https://www.aecswitchgear.com/blog/schneider-easypact-cvs-vs-compact-nsx-key-differences
https://www.aecswitchgear.com/blog/easypact-cvs1000n-4p-ets-2-breaker-supplier-delhi-ncr
https://www.aecswitchgear.com/blog/easylogic-pm1125h-multifunction-meter-distributor-hyderabad-chennai
Get our brochure for more information.
Contact us:-
Mr. Kush Patel :- +91 99048 14793 & sales@aecswitchgear.com