EasyPact CVS1000N 4P ETS 2 breaker supplier Delhi NCR

EasyPact CVS1000N 4P ETS 2 Breaker Supplier in Delhi NCR
Buying a Schneider Electric EasyPact CVS1000N 4P ETS 2 breaker in Delhi NCR? Use LV510241 when requesting a quote. It identifies the 1000 A, four-pole moulded case circuit breaker (MCCB) with an ETS 2.3 electronic trip unit and a 50 kA ultimate short-circuit breaking capacity at 415 V AC. For panel builders, OEMs and maintenance teams, those details matter when the breaker must match an approved single-line diagram or fit an existing panel during a planned shutdown.
Ahmedabad Electric Corporation (AEC) is an authorised Schneider Electric channel partner supplying genuine low-voltage switchgear and industrial automation products across India. We keep selected industrial breakers and panel components in ready stock at our Ahmedabad warehouse. Send us your bill of materials or breaker nameplate for an exact-reference stock check, an itemised quote and a delivery estimate for your site.
Is the CVS1000N 4P ETS 2 right for your panel?
The LV510241 is a candidate for an LT panel incomer or distribution feeder when the design calls for a 1000 A breaker, a switched neutral and protection on the three phase poles. Before releasing the purchase order, check these five points with your panel designer.
Load and conductor capacity. Start with the feeder design current, cable or busbar capacity and temperature inside the enclosure. The breaker’s 1000 A rating and its overload pickup setting are separate decisions. Use Schneider’s derating data for the installation conditions and confirm that the approved setting protects the feeder conductors.
Fault level at the breaker. Compare the prospective short-circuit current at the installation point against the breaker’s 50 kA Icu at 415 V AC, its ultimate breaking capacity at that voltage. Check the service breaking capacity, Ics, against the project specification. If the design relies on an upstream device for backup protection, verify the exact combination against Schneider’s published coordination data.
Neutral switching and protection. Schneider identifies this reference as 4P 3d. Four poles switch, and three poles have overcurrent detection. For panels feeding many single-phase electronic loads, have the designer assess neutral loading and confirm the required protection before selecting the SKU.
Coordination with other breakers. Compare the upstream and downstream devices using their time-current curves and applicable selectivity tables. This matters when a fault on one machine feeder should leave the rest of the production line running.
Mechanical fit and control accessories. For a retrofit, check mounting centres, terminal orientation, busbar spacing and door clearance. Verify the required auxiliary contacts, trip indication, shunt trip or rotary handle by accessory reference. Include the control voltage for any trip coil.
Schneider also lists LV510231 as the 1000 A, three-pole ETS 2 version and LV510242 as the 1000 A, four-pole ETS 6 version. Compare LV510231 when the approved design uses three switched poles. Evaluate LV510242 when the protection schedule calls for ETS 6 functions. Include the complete order code in your enquiry so the quote matches the specified configuration.
Delivery across Delhi NCR industrial areas and nearby clusters
We quote 4–5 days for delivery across Delhi NCR for confirmed in-stock orders, subject to the site PIN code. For factory or project deliveries, include the industrial estate, plot number and receiving hours. We also ship to nearby industrial belts and confirm their lead times by destination.
Delhi: Okhla Industrial Area, Patparganj Industrial Area, Jhilmil, Shahdara, Wazirpur, Lawrence Road, Badli, Narela, Bawana, Bhorgarh, Kanjhawala, Mangolpuri, Nangloi, Baprola, Mayapuri, Naraina and Kirti Nagar.
Noida and Greater Noida: Noida industrial sectors including 63, 64, 65, 80 and 83, plus Surajpur, Kasna, Export Promotion Industrial Park (EPIP) and Ecotech.
Ghaziabad and the eastern NCR belt: Sahibabad Site IV, Meerut Road Site III, Bulandshahr Road Site I, Kavi Nagar Sector 17, Loha Mandi, Loni Industrial Estate, Tronica City, Udyog Kunj in Dasna, and the Masuri–Gulawathi Road industrial belt.
Haryana industrial routes: Gurugram, Udyog Vihar, IMT Manesar, Sohna, Faridabad, Ballabgarh, Palwal, Bahadurgarh, Kundli, Rai, Barhi, Murthal, Kharkhoda, IMT Rohtak, Dharuhera and IMT Bawal.
Rajasthan industrial belt near NCR: Bhiwadi Phases I–IV, Kaharani, Chopanki, Khushkhera, Tapukara, Pathredi, Sare Khurd, Salarpur, Karoli, Neemrana, Shahjahanpur and Ghiloth.
Pan-India switchgear delivery and Gujarat GIDC coverage
We supply Schneider Electric switchgear to Mumbai, Navi Mumbai, Pune, Bengaluru, Chennai, Hyderabad, Kolkata, Ahmedabad and Surat, with 5–6-day delivery to major metro destinations outside Delhi NCR for confirmed in-stock orders. We also serve industrial buyers in Jaipur, Indore, Nagpur, Lucknow, Kanpur, Ludhiana, Chandigarh, Coimbatore, Kochi, Visakhapatnam and Bhubaneswar. Ask for a delivery estimate against your PIN code when requesting the quote.
Ahmedabad, Gandhinagar and Mehsana: Odhav, Vatva, Naroda, Kathwada, Sanand-II (Bol), Dholka, Dhandhuka, Chhatral and Kadi.
Vadodara, Halol and Bharuch: Makarpura, Nandesari, Savli, Vaghodia, Por–Ramangamdi, Halol, Dahej, Saykha, Vilayat, Jhagadia, Ankleshwar and Panoli.
Surat, Navsari and Vapi: Sachin, Pandesara, Hazira, Khatodara, Bardoli, Navsari, Vapi, Pardi, Sarigam and Umargam.
Rajkot, Morbi, Jamnagar and Bhavnagar: Aji, Lodhika (Metoda), Shapar–Veraval, Gondal, Wankaner, Thangadh, Dared, Chitra and Sihor.
Build the rest of your Schneider Electric order
If you are sourcing an entire panel, send the full BOM in one enquiry. We can check the breaker, motor-control and automation references together and show which items are available for the planned dispatch.
Power distribution: EasyPact CVS and ComPacT NSX MCCBs, EasyPact MVS and MasterPacT air circuit breakers, plus Acti9 MCBs and residual current devices for branch circuits.
Motor feeders: EasyPact TVS and TeSys Deca contactors, overload relays and compatible controls. Include the motor full-load current, utilisation category and coil voltage when asking for a match.
Machine automation: Altivar variable frequency drives, Modicon PLCs and Harmony push buttons, indicators and operator interfaces. Share motor ratings and panel control requirements for a reference-level quote.
Request your LV510241 price and stock confirmation from AEC. Call +91 97141 87752 with your quantity, delivery PIN code and required date. For a shutdown replacement, sharing the old breaker’s nameplate and accessory references upfront helps us check the complete requirement before you order.
Frequently asked questions
1. What is the Schneider LV510241 price in Delhi NCR?
Ask AEC for the current price of the exact breaker and any accessories you need. Include the quantity and delivery PIN code so the quote can show GST, freight and the expected dispatch date.
2. Does the CVS1000N 4P ETS 2 provide neutral overcurrent protection?
LV510241 is listed as 4P 3d. The neutral is switched, while overcurrent detection is on the three phases. If the project specifies protected neutral, include that requirement when asking for a breaker selection.
3. Is a 50 kA breaker suitable for a 45 kA fault level?
At 415 V AC, a 50 kA Icu exceeds a calculated 45 kA prospective fault current. Final selection also depends on the required Ics, panel assembly rating and coordination with other protective devices.
4. Can LV510241 replace an older 1000 A, four-pole MCCB?
Confirm the original reference, trip functions, terminal geometry, enclosure clearances and accessory voltages first. Share nameplate photos and a panel drawing for a replacement enquiry, and have the panel designer approve any change.
5. Should I order all accessories with the breaker?
List the accessories specified in your control schematic, such as an auxiliary contact, shunt trip or door-mounted rotary handle. Ask for separate part numbers and stock status so a missing accessory does not hold up panel testing.
6. Can AEC deliver LV510241 to a Noida, Manesar or Faridabad factory?
Yes. The Delhi NCR delivery estimate is 4–5 days for confirmed stocked orders. Share the factory PIN code and receiving hours to confirm the expected arrival before scheduling installation.
Check out our other Schneider electric blogs :-
https://www.aecswitchgear.com/blog/schneider-masterpact-acb-supplier-hazira-surat
https://www.aecswitchgear.com/blog/schneider-altivar-pump-drive-supplier-ankleshwar-gidc
https://www.aecswitchgear.com/blog/schneider-compact-nsx-mccb-quotation-dholera-sir
https://www.aecswitchgear.com/blog/schneider-electric-industrial-switchgear-supplier-hazira
https://www.aecswitchgear.com/blog/schneider-tesys-contactor-coil-price-vapi-gidc
https://www.aecswitchgear.com/blog/schneider-electric-switchgear-supplier-mundra
https://www.aecswitchgear.com/blog/schneider-distributor-thane-belapur-midc
https://www.aecswitchgear.com/blog/schneider-hmi-quotation-for-kalol-gidc
https://www.aecswitchgear.com/blog/schneider-easypact-cvs-vs-compact-nsx-key-differences
Get our brochure for more information.
Contact us:-
Mr. Kush Patel :- +91 99048 14793 & sales@aecswitchgear.com